A new generation of GIT chargers with a power of up to 10 kW, a voltage of up to 50 kV with specific mass-dimensional indicators of up to 10 kg/kW has been developed. An adaptive charger control system with smooth power regulation from 1.5 to 10 kW has been synthesized.
| Parameter | GIS M 50-5/4-10 | GIS M 50-2.5/2-10 |
|---|---|---|
| Rated output voltage | 50 kV (±5%) | 50 kV |
| Adjustment range | 20–50 kV | 20–50 kV |
| Rated energy | 5 kJ | 2.5 kJ |
| Rated output frequency | 2 Hz | 4 Hz |
| Capacity | 10 kW | 10 kW |
| Power consumption | 16.5 kVA | — |
| Efficiency | not less than 0.8 | — |
| Mass | up to 380 kg | — |
| Dimensions | 1550×775×510 mm | — |